EMC Host Connecivity with Emulex Fibre Channel HBAs and CNAs in the Windows Environment
Installation and Configuration
Figure 59 LUNs for target array port
29. Select the number that corresponds to the LUN to be used for
boot, and press Enter.
This displays a window similar to Figure 60.
In the Figure 59 example:
Entry 01 references LUN 00, which holds the Symmetrix
Volume Logix VCM (LUN masking) database, cannot be used
by the host.
Entry 02 references LUN 10 (this is a decimal representation;
which corresponds to a hexadecimal value of 0A), which will
be used for boot.
Note: If no numbered entries appear in the above figure, verify the
following:
For VNX series or CLARiiON systems, verify that the single I/O path
points to the SP that owns the boot LUN.
Verify that array LUN masking settings are configured so that this
adapter has visibility to the appropriate LUN. Refer to your array
software documentation for details.
Figure 60 Selected boot device