Emulex 110 Guia de Instalação Página 199

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 198
Using the Emulex configuration tool
199
Miscellaneous Planning and Procedures
EMC fabric without EMC PowerPath/ATF
(InitLinkFlags=0x00000002 (fabric, auto-link speed),
WaitReady=45, LinkDown=45)
EMC fabric with EMC PowerPath/ATF
(InitLinkFlags=0x00000002 (fabric, auto-link speed),
WaitReady=10, LinkDown=10)
ELXCFG.EXE v1.41a10 enables adapter settings to connect to a
Symmetrix, VNX series, or CLARiiON from the same host while
using the same adapter. This version is distributed with the 2.20a12
and 2.21a0 drivers and is installed from the included Application Kit.
Starting with this version of the configuration tool, as part of a visual
change only, the EMC settings will no longer mask out the
reconfigured generic checkbox options.
To enable custom EMC array configuration settings, a user must start
the utility with a command line option of -- emc. Refer to “Updating
the shortcut” on page 203.
The EMC array auto-configuration settings are no longer presented
automatically as the configuration tool will no longer auto-detect if
an EMC array is present on the fabric. If the -- emc option is enabled,
the configuration tool will automatically mask some of the checkbox
selections, and will present a four-choice EMC array
auto-configuration dialog box under the Configuration-Set menu.
These settings noted below are modified for the global driver defaults
and apply to all adapters in the system. This enables the same
adapter to connect to a Symmetrix, VNX series, or CLARiiON from
the same host while using the same adapter.
The EMC choices will reset the link-speed to Auto. Manually
modifying the link-speed later will no longer remove the checkbox
from the EMC auto-configuration choices.
All adapter global settings are Emulex defaults, with the exception of
the following:
MaximumQueueDepth=32, MaximumLun=255,
UniqueNodeWwns=1,
ShowUnknowns=1, MultipleScsiClaims=1, BrokenRscn=1,
Windows Disk Class Driver Timeout=60s
EMC arbitrated loop without EMC PowerPath/ATF
(InitLinkFlags=0x00000000 (arbitrated loop, auto-link speed),
WaitReady=45, LinkDown=45, TranslateQueueFull=1)