EMC Host Connecivity with Emulex Fibre Channel HBAs and CNAs in the Windows Environment
Miscellaneous Planning and Procedures
EMC arbitrated loop with EMC PowerPath/ATF
(InitLinkFlags=0x00000000 (arbitrated loop, auto-link speed),
WaitReady=10, LinkDown=10)
EMC fabric without EMC PowerPath/ATF
(InitLinkFlags=0x00000002 (fabric, auto-link speed),
WaitReady=45, LinkDown=45, TranslateQueueFull=1)
EMC fabric with EMC PowerPath/ATF
(InitLinkFlags=0x00000002 (fabric, auto-link speed),
WaitReady=10, LinkDown=10)
ELXCFG.EXE v1.41a13 ELXCFG.EXE v1.41a13 has the same settings
as v1.41a10, and is packaged with the 2.21a7 driver kit.
ELXCFG.EXE v1.41a14 enables adapter settings to connect to a
Symmetrix, VNX series, or CLARiiON from the same host while
using the same adapter. This version is distributed with the 2.22a8
driver and is installed from the included Application Kit.
To enable custom EMC array configuration settings, a user must start
the utility with a command line option of -- emc. Refer to “Updating
the shortcut” on page 203.
The EMC array auto-configuration settings are no longer presented
automatically as the configuration tool will no longer auto-detect if
an EMC array is present on the fabric. If the -- emc option is enabled,
the configuration tool will automatically mask some of the checkbox
selections, and will present a four-choice EMC array
auto-configuration dialog box under the Configuration-Set menu.
These settings noted below are modified for the global driver defaults
and apply to all adapters in the system. This enables the same
adapter to connect to a Symmetrix, VNX series, or CLARiiON from
the same host while using the same adapter. The EMC choices will
reset the link-speed to Auto. Manually modifying the link-speed later
will no longer remove the checkbox from the EMC
auto-configuration choices.
All adapter global settings are Emulex defaults, with the exception of
the following:
MaximumQueueDepth=32, MaximumLun=255,
UniqueNodeWwns=1,
ShowUnknowns=1, MultipleScsiClaims=1,BrokenRscn=1,
Windows Disk
Class Driver Timeout=60s
EMC arbitrated loop without EMC PowerPath/ATF