Emulex 110 Guia de Instalação Página 235

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 234
Problems and solutions
235
Troubleshooting
Problems and solutions
This section contains known problems and solutions.
Problem 1
Problem 85340 Disk manager Rescan Disks does not find
MetaLUNs. Windows 2000 requires an OS reboot to size (discover)
MetaLUNs. A conventional LUN is sized successfully with a Rescan
Disks.
Solution Upgrade to the latest adapter driver. This was corrected in 2.20a12
and later drivers.
Problem 2
EMC Knowledge base solution emc67559 Fibre Channel tape
devices disappearing under Windows 2000.
Solution Upgrade to the latest adapter driver. This was corrected in 2.21a0 and
later drivers.
Problem 3
EMC Knowledge base solution emc69097 If using adapters
connected to both VNX series or CLARiiON SPs, without PowerPath
installed, duplicate LUNs will be visible in the Device Manager and
Disk Manager. Only one instance of the LUN will be accessible, and
all other matching mappings will be listed as Unknown, Unreadable,
and Unallocated.
Solution This is normal behavior when multiple paths are available,
PowerPath is not installed, and the initiator type is registered in
PowerPath mode (array default depending on core code revision).
Problem 4
EMC Knowledge base solution emc70952 While attempting to
install the Emulex HBAnyware Application Kit without removing a
previously installed Emulex HBAnyware Application Kit, the host
may generate the following error:
STOP 50 (PAGE FAULT IN NON PAGED AREA).
Solution Uninstall any existing HBAnyware Application Kit before installing
an updated HBAnyware Application Kit. This problem was corrected
in the application kit contained in the driver package for 2.21a7 and
later drivers.
Vista de página 234

Comentários a estes Manuais

Sem comentários