Driver for Linux -Troubleshooting Section Page 105
ELS Events (0100 - 0199)
elx_mes0100: FLOGI failure
DESCRIPTION: An ELS FLOGI command that was sent to the fabric failed.
DATA: (1) ulpStatus (2) ulpWord[4]
SEVERITY: Information
LOG: LOG_ELS verbose
ACTION: No action needed, informational.
elx_mes0101: FLOGI completes successfully
DESCRIPTION: An ELS FLOGI command that was sent to the fabric succeeded.
DATA: (1) ulpWord[4] (2) e_d_tov (3) r_a_tov (4) edtovResolution
SEVERITY: Information
LOG: LOG_ELS verbose
ACTION: No action needed, informational.
elx_mes0102: PLOGI completes to NPort <nlp_DID>
DESCRIPTION: The HBA performed a PLOGI into a remote NPort.
DATA: (1) ulpStatus (2) ulpWord[4] (3) disc (4) num_disc_nodes
SEVERITY: Information
LOG: LOG_ELS verbose
ACTION: No action needed, informational.
elx_mes0103: PRLI completes to NPort <nlp_DID>
DESCRIPTION: The HBA performed a PRLI into a remote NPort.
DATA: ((1) ulpStatus (2) ulpWord[4] (3) num_disc_nodes
SEVERITY: Information
LOG: LOG_ELS verbose
ACTION: No action needed, informational.
elx_mes0104: ADISC completes to NPort <nlp_DID>
DESCRIPTION: The HBA performed a ADISC into a remote NPort.
DATA: (1) ulpStatus (2) ulpWord[4] (3) disc (4) num_disc_nodes
SEVERITY: Information
LOG: LOG_ELS verbose
ACTION: No action needed, informational.
elx_mes0105: LOGO completes to NPort <nlp_DID>
DESCRIPTION: The HBA performed a LOGO to a remote NPort.
DATA: (1) ulpStatus (2) ulpWord[4] (3) num_disc_nodes
SEVERITY: Information
LOG: LOG_ELS verbose
ACTION: No action needed, informational.