Vista de página 350
Miscellaneous Events (1200 - 1299)
elx_mes1200: Cannot unload driver while lpfcdiag interface is active
DESCRIPTION: An attempt was made to unload the driver while the DFC interface
was active.
DATA: (1) refcnt (2) instance
SEVERITY: Error
LOG: Always
ACTION: Exit any application that uses the DFC diagnostic interface before
attempting to unload the driver.
elx_mes1201: lpfc_kmalloc: bad phba
DESCRIPTION: The driver manages its own memory for internal use. This error
indicates a problem occurred in the driver memory management routines. This
error could also indicate the host system is low on memory resources.
DATA: 1) size (2) type (3) fc_idx_dmapool
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a driver or host operating system problem. If the
problem persists, report the error to Technical Support.