elx_mes0409: Memory Buffer Pool is out of buffers
DESCRIPTION: A driver memory buffer pool is exhausted.
DATA: (1) seg (2) fc_free (3) fc_mbox.q_cnt (4) fc_memhi
SEVERITY: Error
LOG: Always
ACTION: Configure more resources for that buffer pool. If the problem persists,
report the error to Technical Support.
elx_mes0410: Cannot find virtual addr for mapped buf on ring <num>
DESCRIPTION: The driver cannot find the specified buffer in its mapping table.
Thus it cannot find the virtual address needed to access the data.
DATA: (1) first (2) q_first (3) q_last (4) q_cnt
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a software driver or firmware problem. If
problems persist report these errors to Technical Support.