Emulex LP10000ExDC Manual do Utilizador Página 228

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 366
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 227
elx_mes0220: FDMI rsp failed
DESCRIPTION: An error response was received to FDMI request.
DATA:(1) SWAP_DATA16(fdmi_cmd)
SEVERITY: Information
LOG: LOG_DISCOVERY verbose
ACTION: The fabric does not support FDMI, check fabric configuration.
elx_mes0221: FAN timeout
DESCRIPTION: A link up event was received without the login bit set, so the driver
waits E_D_TOV for the Fabric to send a FAN. If no FAN if received, a FLOGI will
be sent after the timeout.
DATA: None
SEVERITY: Warning
LOG: LOG_DISCOVERY verbose
ACTION: None required. The driver recovers from this condition by issuing a
FLOGI to the fabric.
Emulex Documentation, Drivers and Software
228
Vista de página 227
1 2 ... 223 224 225 226 227 228 229 230 231 232 233 ... 365 366

Comentários a estes Manuais

Sem comentários