lpfcN: 12 : ELS Retry failed
If an ELS command fails, it may be retried up to 3 times. This message will be
recorded if the driver gives up retrying a specific ELS command. The value of the
ELS command and the remote PortID will be recorded.
ACTION: If the ELS command is a PRLI, and the destination PortID is not an FCP
target, no action is needed. Otherwise, check physical connections to the Fibre
Channel network and the state the remote PortID is in.
WARNING ELS verbose fcelsb.c
lpfcN: 13 : Service Level Interface selected
Either a CONFIG_PORT (SLI2) or PART_SLIM (SLI1) mailbox command was
issued. The SLI selected, 1 or 2, and the virtual address of the SLIM will be
recorded.
ACTION: None needed.
WARNING MISC verbose fcmboxb.c
lpfcN: 14 : Memory Buffer Pool is below low water mark
A driver memory buffer pool is low on buffers. The buffer pool number and low
water mark are recorded.
ACTION: None needed.
WARNING MISC verbose fcmemb.c