RSCNDELAY
Minimum value = 0, maximum value = 60 (decimal). Default = 0;
RSCNDELAY specifies the time, in seconds, to delay a query to the Fibre Channel
Name Server after a State Change Notification. The default value should be
satisfactory for most cases.
RSCNZONE
Boolean parameter: 0 = not selected, 1 = selected. Default is RSCNZONE=1;
If set to 1 (default), always query the Fibre Channel Name Server after a State Change
Notification. If set to 0, query only when necessary.
SCANDOWN
Boolean parameter: 0 assigns to each device in the loop a fixed SCSI ID in the range of
0 to 125. 1 assigns to each device in the loop a fixed SCSI ID in the range of 125 to 0.
This parameter applies ONLY to private loop configurations.
Scan Direction for Loop Auto Binding:
When SCANDOWN=0, this option assigns to each device in the loop a fixed
SCSI ID in the range 0 to 125, in increasing order depending on the AL_PA of
the device. For instance, the device at AL_PA 1 will always have the SCSI ID
x01, and the device at AL_PA xEF will always have the SCSI ID 125. This is
the default, and matches the behavior of earlier drivers.
When SCANDOWN=1, this option assigns to each device in the loop a fixed
SCSI ID in the range 125 to 0 , in decreasing order depending on the AL_PA of
the device. For instance, the device at AL_PA xEF will always have the SCSI
ID 0, and the device at AL_PA x01 will always have the SCSI ID 125.